+91 11 43117900
Banner
DIN FLRY-B-72251
Features

PVC wire with conductor construction type B and thin insulation

Conductor

Soft-annealed electrolytic copper E-Cu 58 F21 according to DIN 40500, Part 4, bare al Pair 5, tinned. Conductor construction according to DIN 72551, Part 6, type B and ISO 6722.

Insulation

Plasticized PVC with properties according to DIN 72551 and ISO 6722, class B.

Construction and Performance
Conductor construction Insulated conductor
Nominal Cross Section mm^2 "No. of individual
wires"
"Diameter of individual
wire Max. Mm."
Conductor max. mm. Resistance at 20°C bare/tinned Outer - ø Insulation Thickness min mm Weight approx
min. max mm Limit Deviation mm kg/1000m
mΩ/m mΩ/m
0.35 12 0.21 0.90 47.80 / - 52.0 / 54.5 1.4 -0.2 0.20 4.5
0.5 16 0.21 1.00 34.10 / - 37.1 /38.2 1.6 -0.2 0.22 6.6
0.75 24 0.21 1.20 22.70/ - 24.7 / 25.4 1.9 -0.2 0.24 9.0
1 32 0.21 1.35 17.00 / - 18.5 / 19.1 2.1 -0.2 0.24 11.0
1.5 30 0.26 1.70 11.70 / - 12.7 / 13.0 2.4 -0.2 0.24 16.0
2 30 0.31 1.90 8.62 / - 9.31 / 9.59 2.6 -0.2 0.24 22.0
2.5 50 0.26 2.20 7.00 / - 7.60 / 7.80 3.0 -0.3 0.28 6.0
3 45 0.31 2.40 5.76 / - 6.21 / 640 3.2 -0.3 0.28 32.5
4 56 0.31 2.75 4.32 / - 4.70 / 4.80 3.7 -0.3 0.32 42.0
6 84 0.31 3.30 2.85 / - 3.10 / 320 4.3 -0.3 0.32 61.0