+91 11 43117900
Banner

DATA CABLE CATEGORY 5e

Horizontal Wiring Non-CMR LAN Cable
Application
Suitable for both voice and high speed data applications in Local Area Networks. Compliances AS/NZS 3080:2003 (Cat 5e)
ISO/IEC 11801 Ed.2 (Cat 5e)
10 Base-T (IEEE 802.3) ANSI/TIA 568-C.2 (Cat 5e)
100 Base-T (IEEE 802.3) AS/CA S008:2010
4/16 Mbps Token Ring (IEEE 802.5) UL Verified (Cat 5e)
 52/155 Mbps ATM IEC 60332-1
 100 VG-AnyLAN Conductor Plain Annealed Copper Wire (24 AWG)
100 Mbps TP-PMD (ANSI X3T9.5) Insulation High Speed Data Grade Polyolefin
1000 Base-T (Gigabit Ethernet) Pair 1 – White/Blue & Blue
Broadband and baseband analogue video Pair 2 – White/Orange & Orange
 Digital video Pair 3 – White/Green & Green
Environmental Performance Pair 4 – White/Brown & Brown.
Installation Temperature -10°C to 40°C Sheath Flame Retardant PVC
Operating Temperature -20°C to 60°C Cable printed with metre marking
Technical Specifications
Item Number Nominal Overall Diameter Conductor Approx. Mass Minimum Bending Radius mm Standard Packing Reelex Box
Number Of Pairs Number & Diameter Of Wires (No./mm) 305m
Sclcat5e 4.9 4 1/0.51 29 20
Electrical Characteristics
Property Value Units
DC Conductor Resistance Max. 9.38 Ω/100m
Resistance Unbalance Max. 2%
Mutual Capacitance Nom. @1kHz 5.6 nF/100m
Capacitance Unbalance pair/ground Max. @1kHz 160 pF/100m
Characteristic Impedance 0.772 -100 MHz 100+15 Ω
Maximum Delay Skew 1.0-100 MHz 45 ns/100m
Velocity of Propagation 68% Speed of Light
Maximum Propagation Delay 10 MHz 545 ns/100m
Frequency
MHz dB/100m (max.) dB (min.) dB (min.) dB/100m (min.) dB/100m (min.) dB (min.)
0.772 1.8 67 64 - - -
1 2.04 65.3 62.3 64 61 20
4 4.05 56.3 53.3 52 49 23
8 5.77 51.8 48.8 45.9 42.9 24.5
10 6.47 50.3 47.3 44 41 25
16 8.25 47.2 44.2 39.9 36.9 25
20 9.27 45.8 42.8 38 35 25
25 10.42 44.3 41.3 36 33 24.3
31.25 11.72 42.9 39.9 34.1 31.1 23.6
62.5 16.99 38.4 35.4 28.1 25.1 21.5
100 21.98 35.3 32.3 24 21 20.1
Note:
  • These cables are not to be regarded as power cables or for the direct connection of equipment to mains power supplies.
  • All Limits stated are based on measurements made or corrected to 20 ºC.
  • Attenuation, NEXT, FEXT and RL are obtained by swept frequency measurements
  • Characteristic Impedance is derived by applying a smoothing function to swept frequency input impedance measurements
  • NVP is supplied for installation equipment to return cable jacket length.

Note: Values typical, guaranteed within 5 %